China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-DRSL(DC)-2000mA Split Core Leakage current sensor

TesterMeter-DRSL(DC)-2000mA Split Core Leakage current sensor

2023-07-07 08:49:16  

DC 2000mA Split core leakage current sensor transducer

  • Main Feature : Xtester-DRSL(DC)-2000mA Split Core Leakage current sensor
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

TECHNICIAL SPECIFICATION

Click to download:TesterMeter-DRSL(DC)-2000mA Specification

TesterMeter
Model Number-DRSL-2000mA
Diameter
φ33mm
Rated input Current (IPN)5010050010002000mA(DC)
Primary Current Measure range(IP)0~±1000~±1500~±6000~±12000~±2200mA
Rated output voltage of secondary sideDC ±5V, 4-20mA, 0-20mA (±1%)V
Power Supply Voltage (VCC)DC ±12V~±15V  (±5%)V
Current consumption<20 (VCC=±12V)mA
Galvanic isolation (Vd)2.5KV /50Hz/1min
Linearity (εL)<1%FS
Offset Voltage V0<±50 (TA=25℃)  mV
Offset Voltage drift VOT<±2.5( IP=0  TA =-10~+60℃)mV/℃
Operating temperature TA-10~+60
Storage temperature TS-20~+70
Load resistance RL≥10KΩ
Matters needing attention:
  • The wrong connection may cause sensor damage. After the sensor is energized, the same phase voltage is measured at the output when the current wire cross the sensor center according the direction arrow indicating label.

  • The output range of the sensor can be adjusted according to the user's needs.

  • During the installation process, before closing the jaw, make sure the connecting interface is aligned, not forcibly closed

Hall Current Sensor  Selection Guide

Model NumberRangeDiameterOutputPower Supply

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRB1

50,100,200,300A20mm(Close Loop)50,100,100,150mADC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1D

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)2.5±1.25V  ( ±1%)DC  +5V (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1AC

50,100,200,300,400,500A(AC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK3D

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)2.5V±1.25V    ±1%DC  +5V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK3

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK5

300,500,600,800,1000,1500A(AC/DC)37*42.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH2

300,400,600,800,1000,2000A(AC/DC)40.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH4

600,800,1000,2000,2500,3000A(AC/DC)80mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH5

600,1000,2000,3000,5000A(AC/DC)42*400mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DS10000LC

1000,3000,5000,8000A,10000A(AC/DC)140*36mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DS8000DKL

10000,20000,30000,40000,60000A,80000A(AC/DC)120mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DS4000IAX

500,800,1000,1500,2500A,4000A(AC/DC)64*21mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1500DFA

200,400,600,800,1000A,1500A(AC/DC)
40*30.2mm(Open Loop)
4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS20000IC

5000,7500,10000,15000,20000A,(AC/DC)210*100mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS10000IB

2000,3000,5000,8000,10000A,(AC/DC)140*50mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS6000FKF

300,600,1000,2000,4000,6000A,(AC/DC)φ62mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS5000LA

600,1000,2000,3000,5000A,(AC/DC)104*36mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS5000LAA

500,1000,2000,3000,5000A,(AC/DC)102*38mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2500LF2

500,1000,1500,2000,2500A,(AC/DC)85*27mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000L

300,500,800,1000,2000A,(AC/DC)64*16mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000GA

400,500,800,1000,2000A,(AC/DC)51*13mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000FB

500,800,1000,1500.2000A,(AC/DC)φ60.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000T

100,200,300,400,500,600,1000A,(AC/DC)φ32mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000FD

200,400,700,1000A,(AC/DC)φ17.5mm4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000CF

200,400,600,800,1000A,(AC/DC)40.5*20.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS800FKH.80.jpg

TesterMeter- DS800FKH

100,200,300,500,800A,(AC/DC)φ35mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600P.80.jpg

TesterMeter- DS600P

50,100,200,300,400,500,600A,(AC/DC)26*12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS600F2.80.jpg

TesterMeter- DS600F2

100,200,300,400,500,600A,(AC/DC)φ28mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600C.80.jpg

TesterMeter- DS600C

50,100,200,300,400,500,600A,(AC/DC)20.5*10.2mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS400FKC.80.jpg

TesterMeter- DS400FKC

50,100,150,200,300,400A,(AC/DC)φ12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS040H.80.jpg

TesterMeter- DS040H

10,20,30,40A(AC/DC)φ5mm1±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS2000DKO.80.jpg

TesterMeter-DS2000DKO

500,1000,5000,8000

12000,20000(AC/DC)

φ80mm4or5±1%DC  ±12V- ±15V  (±5%)



Telephone
Email
Map
QQ Chat