China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Testermeter- CS600EK1T24-L(4-20mA) series Hall Detachable Current Sensor

Testermeter- CS600EK1T24-L(4-20mA) series Hall Detachable Current Sensor

2025-02-23 11:21:24  

CS600EK1T24-L(4-20mA) series Hall Detachable Current Sensor

  • Main Feature :
  • Serial No. : Zoe689
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Testermeter- CS600EK1T24-L(4-20mA) series Hall Detachable Current Sensor

  

Electrical Parameters

Model Number

CS050EK1T24-L

CS100EK1T24-L

CS200EK1T24-L

CS300EK1T24-L

CS500EK1T24-L

CS600EK1T24-L

IPN (Primary Input Current)

0~50 A

0~100 A

0~200 A

0~300 A

0~500 A

0~600 A

IP (Primary Current Measurement Range)

0~75 A

0~150 A

0~300 A

0~450 A

0~750 A

0~900 A

IOUT (Secondary Output Current)

4~20 (±1%) mA

4~20 (±1%) mA

4~20 (±1%) mA

4~20 (±1%) mA

4~20 (±1%) mA

4~20 (±1%) mA

RL (Load Resistance)

80~650 Ω

80~650 Ω

80~650 Ω

80~650 Ω

80~650 Ω

80~650 Ω

VC (Power Supply Voltage)

+24 (±5%) V

+24 (±5%) V

+24 (±5%) V

+24 (±5%) V

+24 (±5%) V

+24 (±5%) V

IC (Current Consumption)

25 + IOUT mA

25 + IOUT mA

25 + IOUT mA

25 + IOUT mA

25 + IOUT mA

25 + IOUT mA

Vd (Insulation Voltage)

5kV effective value / 50Hz / 1 minute

5kV effective value / 50Hz / 1 minute

5kV effective value / 50Hz / 1 minute

5kV effective value / 50Hz / 1 minute

5kV effective value / 50Hz / 1 minute

5kV effective value / 50Hz / 1 minute

εL (Linearity)

±1 %FS

±1 %FS

±1 %FS

±1 %FS

±1 %FS

±1 %FS

I0 (Zero Offset Current)

TA = 25°C 4±0.1 mA

TA = 25°C 4±0.1 mA

TA = 25°C 4±0.1 mA

TA = 25°C 4±0.1 mA

TA = 25°C 4±0.1 mA

TA = 25°C 4±0.1 mA

IOM (Magnetic Offset Current)

IPN→0 <0.1 mA

IPN→0 <0.1 mA

IPN→0 <0.1 mA

IPN→0 <0.1 mA

IPN→0 <0.1 mA

IPN→0 <0.1 mA

IOT (Offset Current Temperature Drift)

IPN=0, TA = -25~+85°C <0.005 mA/°C

IPN=0, TA = -25~+85°C <0.005 mA/°C

IPN=0, TA = -25~+85°C <0.005 mA/°C

IPN=0, TA = -25~+85°C <0.005 mA/°C

IPN=0, TA = -25~+85°C <0.005 mA/°C

IPN=0, TA = -25~+85°C <0.005 mA/°C

Tr (Response Time)

≤7 μs

≤7 μs

≤7 μs

≤7 μs

≤7 μs

≤7 μs

f (Frequency Bandwidth)

DC~20 kHz

DC~20 kHz

DC~20 kHz

DC~20 kHz

DC~20 kHz

DC~20 kHz

TA (Operating Temperature)

-25~+85°C

-25~+85°C

-25~+85°C

-25~+85°C

-25~+85°C

-25~+85°C

TS (Storage Temperature)

-40~+100°C

-40~+100°C

-40~+100°C

-40~+100°C

-40~+100°C

-40~+100°C

m (Weight)

68 g

68 g

68 g

68 g

68 g

68 g

 

Usage Instructions

1. Incorrect wiring may cause damage to the sensor. The corresponding current value can be measured at the output when the current flows through the sensor in the direction indicated by the arrow.

2. The output amplitude of the sensor can be adjusted appropriately according to user requirements.

3. Sensors with different rated input currents can be customized based on user needs.

 1.png



Telephone
Email
Map
QQ Chat