China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-HT681X Series Programmable DC Power Supply
TesterMeter-HT681X Series Programmable DC Power Supply
TesterMeter-HT681X Series Programmable DC Power Supply
TesterMeter-HT681X Series Programmable DC Power Supply
TesterMeter-HT681X Series Programmable DC Power Supply
TesterMeter-HT681X Series Programmable DC Power Supply

TesterMeter-HT681X Series Programmable DC Power Supply

2023-07-20 15:53:29  

TesterMeter-HT681X Series Programmable DC Power Supply

  • Main Feature :
  • Serial No. : Lisa0255
Contact US For Quotation  Email:464560351@qq.com  Whatsapp&Wechat:+8618620373879

Overview

HT68 series power supply is high performance single-output programmable DC power supply with communication interface, possessing the character of fast rise time speed (The rise speed of HT6811 power supply can be less than 10mS and the HT6851 can be less than 20mS). The combination of bench-top and system features in HT68 power supplies provides versatile solutions for your design and test requirements. The HT68 series can not only be programmed through the keyboard on the panel, but also be functioned as voltmeter and milliohm meter, which will bring great convenience to the users. As a regeneration product of ordinary programmable power supplies, HT68 series power supply is more cost-effective.

HT6831 power supply, a new generation of programmable linear power supply, are designed with high-speed dynamic programming output (voltage 0-30V, 1ms rising time), high current accuracy (0.001mA resolution) and low internal resistance, which can satisfy all the test requirements. Meanwhile, the voltage level switch works without relay, which will cause the fast switch between high voltage and low voltage. Moreover, HT6831 power supply provides the best solutions for cellphone research, micro-electronics lab, research institute and special users requiring power supply with low current but high accuracy.

Features

  • Low ripple and noise

  • High resolution and accuracy (0.1mV/0.01mA, HT6831 reaches up to 0.001mA)

  • Built-in a high-accuracy 5 1/2 voltmeter and milliohm meter

  • Supporting high-accuracy and dynamic programming output

  • High-luminance VFD screen and two lines& four ways display

  • Smart fan will be automatically initiated according to the temperature

  • Supporting remote voltage compensation and multidata storage

  • Supporting external trigger input and output

  • Power-on-self-test, software calibration and standard rack mountable

  • Supporting RS232/RS485/USB interface

Application

  • Laboratory testing

  • Power electronics production line testing

  • Other automatic testing systems, etc.

  • Functioning as voltmeter and milliohm meter

HT68 Series 30W ~600W Power Supply Technical Specification

ModelHT6811HT6812HT6813HT6831
Output RatingVoltage0-30V0-75V0-150V0-30V
Current0-5A0-2A0-1A0-1A
Load RegulationVoltage<0.01%+0.5mV<0.01%+0.5mV<0.01%+0.5mV<0.01%+0.5mV
Current<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA
Setting Value ResolutionVoltage0.5mV1mV2mV0.5mV
Current0.1mA0.05mA0.01mA0.01mA
Readback Value ResolutionVoltage0.1mV0.1mV1mV0.1mV
Current0.01mA0.01mA0.01mA0.001mA
Setting Value AccuracyVoltage0.01%+2mV0.01%+5mV0.01%+10mV0.01%+2mV
Current0.05%+1mA0.05%+0.5mA0.05%+0.1mA0.05%+0.1mA
Readback Value AccuracyVoltage0.02%+5mV0.02%+15mV0.02%+35mV0.02%+5mV
Current0.1%+5mA0.05%+2mA0.05%+1mA0.02%+1mA
RippleVoltage3mvp-p5mvp-p10mvp-p10mvp-p
Current2mA rms1mA rms0.5mA rms0.5mA rms
Voltmeter Accuracy0-12V Accuracy: 0.02%+2mV


0-58V Accuracy: 0.02%+5mV

Milli ohmmeter Accuracy10W. 0-1000mΩ Accuracy: 0.2%+3mΩ


1000-10000mΩ Accuracy: 0.2%+6mΩ

Working Condition0-40°C; 0-90%RH
Power RequiredAC 120V/220V±10%; 50/60HZ
Weight6.5Kg
Dimension214mmW x 101.5mmH x 365mmD
ModelHT6851HT6852HT6853
Output RatingVoltage0-6V0-30V0-75V
Current0-60A0-20A0-8A
Load RegulationVoltage<0.01%+1mV<0.01%+1mV<0.01%+1mV
Current<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA
Setting Value ResolutionVoltage0.1mV0.5mV1mV
Current1mA0.5mA0.2mA
Readback Value ResolutionVoltage0.1mV0.1mV0.1mV
Current0.1mA0.1mA0.1mA
Setting Value AccuracyVoltage0.01%+1mV0.01%+5mV0.01%+10mV
Current0.05%+6mA0.05%+2mA0.05%+1mA
Readback Value AccuracyVoltage0.02%+2mV0.02%+5mV0.02%+15mV
Current0.05%+45mA0.05%+20mA0.05%+8mA

Ripple

Voltage3mvp-p5mvp-p7mvp-p
Current15mA rms7mA rms4mA rms
Voltmeter Accuracy0-12V Accuracy: 0.02%+2mV


0-58V Accuracy: 0.02%+5mV

Milliohmmeter Accuracy10W. 0-1000mΩ Accuracy: 0.2%+3mΩ


1000-10000 mΩ Accuracy: 0.2%+6mΩ

Working Condition0-40°C; 0-90%RH
Power RequiredAC 120V/220V+10%; 50/60HZ
Weight28Kg
Dimension428mmW×88mmH×453.5mmD

HT687X series Power Supply Technical Specification

ModelHT6871HT6872HT6873HT6874
Output RatingVoltage0-15V0-30V0-75V0-100V
Current0-60A0-35A0-15A0-11A
Load RegulationVoltage<0.01%+1mV<0.01%+1mV<0.01%+1mV<0.01%+1mV
Current<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA
Setting Value ResolutionVoltage0.1mV0.5mV2mV2mV
Current1mA0.5mA0.2mA0.2mA
Readback Value ResolutionVoltage0.1mV0.1mV0.1mV1mV
Current0.1mA0.1mA0.1mA0.1mA
Setting Value AccuracyVoltage0.01%+1mV0.01%+5mV0.01%+10mV0.01%+15mV
Current0.05%+6mA0.05%+2mA0.05%+1mA0.05%+1mA
Readback Value AccuracyVoltage0.03%+3mV0.03%+5mV0.03%+15mV0.03%+25mV
Current0.05%+45mA0.05%+25mA0.05%+12mA0.05%+10mA

Ripple

Voltage4mvp-p5mvp-p6mvp-p8mvp-p
Current15mA rms8mA rms3mA rms2.5mA rms
Voltmeter Accuracy0-12V Accuracy: 0.02%+2mV


0-58V Accuracy: 0.02%+5mV

Milliohmmeter Accuracy10W. 0-1000mΩ Accuracy: 0.2%+3mΩ


1000-10000mΩ Accuracy: 0.2%+6mΩ

Working Condition0-40°C; 0-90%RH
Power RequiredAC 125V/220V+10%; 50/60HZ
Weight45Kg
Dimension482mmW×184.5mmH×531mmD

Options & Accessories

Optional Communication Cable- HT6131 RS232 interface


Telephone
Email
Map
QQ Chat