China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-Mean Well RSP-200 Series 200W Single Output with PFC Function,enclosed type AC/DC power supply

TesterMeter-Mean Well RSP-200 Series 200W Single Output with PFC Function,enclosed type AC/DC power supply

2024-03-11 14:29:32  

TesterMeter-Mean Well RSP-200 Series 200W Single Output with PFC Function,enclosed type AC/DC power supply

  • Main Feature :
  • Serial No. : Xtester2300673
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

TesterMeter-Mean Well RSP-200 Series 200W Single Output with PFC Function,enclosed type AC/DC power supply

Features

  1. Universal AC input / Full range

  2. Built-inactive PFC function

  3. High efficiency up to 90%

  4. Cooling by free air convection

  5. Protections: Short circuit / overload / over voltage/ over temperature

  6. optional conformal coating

  7. LED indicator for power on

AppIications

  1. Factory control or automation apparatus . Test and measurement instrument

  2. Laser related machine

  3. Burn-in facility

  4. RF application

Description

RSP-200 is a 200w single output enclosed type AC/DC power supply. This series operates for 88~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled  by free air convection,working for the temperature up to 70℃ .

图片关键词

Specification

MODEL

RSP-200-2.5

RSP-200-3.3

RSP-200-4

RSP-200-5

RSP-200-7.5

RSP-200-12


DC VOLTAGE

2.5V

3.3V

4V

5V

7.5V

12V


RATED CURRENT

40A

40A

40A

40A

26.7A

16.7A


CURRENT RANGE

0 ~ 40A

0 ~ 40A

0 ~ 40A

0 ~ 40A

0 ~ 26.7A

0 ~ 16.7A


RATED POWER

100W

132W

160W

200W

200.25W

200.4W


RIPPLE & NOISE (max.) Note.2

100mVp-p

100mVp-p

100mVp-p

150mVp-p

150mVp-p

150mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

2.35 ~ 2.85V

2.97 ~ 3.8V

3.7 ~ 4.3V

4.5 ~ 5.5V

6 ~ 9V

10 ~ 13.2V


VOLTAGE TOLERANCE  Note.3

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

±1.0%


LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.3%


LOAD REGULATION

±1.5%

±1.5%

±1.0%

±1.0%

±1.0%

±0.5%


SETUP, RISE TIME

1500ms, 50ms/230VAC         3000ms, 50ms/115VAC at full load


HOLD UP TIME (Typ.)

8ms at full load     230VAC /115VAC


VOLTAGE RANGE          Note.4

88 ~ 264VAC          124 ~ 370VDC


FREQUENCY RANGE

47 ~ 63Hz


POWER FACTOR (Typ.)

PF>0.95/230VAC         PF>0.98/115VAC at full load

INPUT

EFFICIENCY (Typ.)

79.5%

81.5%

84%

85.5%

89%

89%


AC CURRENT (Typ.)

2A/115VAC           1.1A/230VAC

2.5A/115VAC           1.3A/230VAC


INRUSH CURRENT (Typ.)

20A/115VAC         40A/230VAC


LEAKAGE CURRENT

<1mA / 240VAC

 

 

PROTECTION

OVERLOAD

105 ~ 135% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

2.88 ~ 3.5V

3.8 ~ 4.62V

4.5 ~ 5.6V

5.75 ~ 7V

9.4 ~ 10.9V

13.8 ~ 16.2V

Protection type : Shutdown o/p voltage, re-power on to recover


OVER TEMPERATURE

Shutdown o/p voltage, recovers automatically after temperature goes down


WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")


WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT

STORAGE TEMP., HUMIDITY

-40 ~ +85℃ , 10 ~ 95% RH


TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 45℃)


VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes


SAFETY STANDARDS

UL62368-1,TUV BS EN/EN62368-1, EACTPTC 004,CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1, Dekra EN 61558-1/2-16,IEC 61558-1/2-16(for 12Vor higher models) approved

SAFETY &

WITHSTAND VOLTAGE

I/P-O/P:3KVAC    I/P-FG:2KVAC    O/P-FG:0.5KVAC

EMC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

(Note 5)

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B , GB17625.1


EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020


MTBF

2078.1K hrs min.      Telcordia SR-332 (Bellcore) ; 224.5K hrs min.      MIL-HDBK-217F (25℃)

OTHERS

DIMENSION

215*115*30mm (L*W*H)


PACKING

0.72Kg; 15pcs/11.8Kg/0.67CUFT

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃  of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. please check the derating curve for more details.

5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by

mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMl testing of component power supplies.”

6. For charging related applications, please consult Mean well for details.

7. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSp-200-2.5/-3.3/-4/-5/-7.5/-12/-13.5/-15)

8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft) .

Specification

MODEL

RSP-200-13.5

RSP-200-15

RSP-200-24

RSP-200-27

RSP-200-36

RSP-200-48


DC VOLTAGE

13.5V

15V

24V

27V

36V

48V


RATED CURRENT

14.9A

13.4A

8.4A

7.5A

5.56A

4.2A


CURRENT RANGE

0 ~ 14.9A

0 ~ 13.4A

0 ~ 8.4A

0 ~ 7.5A

0 ~ 5.56A

0 ~ 4.2A


RATED POWER

201.15W

201W

201.6W

202.5W

200.16W

201.6W


RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

200mVp-p

220mVp-p

240mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

12 ~ 15V

13.5 ~ 18V

20 ~ 26.4V

26 ~ 31.5V

32.4 ~ 39.6V

41 ~ 56V


VOLTAGE TOLERANCE  Note.3

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%


LINE REGULATION

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

±0.2%


LOAD REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%


SETUP, RISE TIME

1500ms, 50ms/230VAC         3000ms, 50ms/115VAC at full load


HOLD UP TIME (Typ.)

8ms at full load     230VAC /115VAC


VOLTAGE RANGE          Note.4

88 ~ 264VAC          124 ~ 370VDC


FREQUENCY RANGE

47 ~ 63Hz


POWER FACTOR (Typ.)

PF>0.95/230VAC         PF>0.98/115VAC at full load

INPUT

EFFICIENCY (Typ.)

89%

89.5%

89.5%

89%

90%

90%


AC CURRENT (Typ.)

2.5A/115VAC           1.3A/230VAC


INRUSH CURRENT (Typ.)

20A/115VAC         40A/230VAC


LEAKAGE CURRENT

<1mA / 240VAC

 

 

PROTECTION

OVERLOAD

105 ~ 135% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

15.7 ~ 18.4V

18.8 ~ 21.8V

27.6 ~ 32.4V

32.9 ~ 38.3V

41.4 ~ 48.6V

58.4 ~ 68V

Protection type : Shutdown o/p voltage, re-power on to recover


OVER TEMPERATURE

Shutdown o/p voltage, recovers automatically after temperature goes down


WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")


WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT

STORAGE TEMP., HUMIDITY

-40 ~ +85℃ , 10 ~ 95% RH


TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 45℃)


VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes


SAFETY STANDARDS

UL62368-1,TUV BS EN/EN62368-1, EACTPTC 004,CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1, Dekra EN 61558-1/2-16,IEC 61558-1/2-16(for 12Vor higher models) approved

SAFETY &

WITHSTAND VOLTAGE

I/P-O/P:3KVAC    I/P-FG:2KVAC    O/P-FG:0.5KVAC

EMC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

(Note 5)

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,EAC TP TC 020, CNS13438, GB9254 Class B , GB17625.1


EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020


MTBF

2078.1K hrs min.      Telcordia SR-332 (Bellcore) ; 224.5K hrs min.      MIL-HDBK-217F (25℃)

OTHERS

DIMENSION

215*115*30mm (L*W*H)


PACKING                                 0.72Kg; 15pcs/11.8Kg/0.67CUFT

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃  of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. please check the derating curve for more details.

5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that    it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMl testing of component power supplies.”

6. For charging related applications, please consult Mean well for details.

7. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSp-200-2.5/-3.3/-4/-5/-7.5/-12/-13.5/-15)

8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft) .

图片关键词


Telephone
Email
Map
QQ Chat