Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
TesterMeter-QP-150 series 150W Quad Output with PFC Function, Enclosed Type AC/DC Power Supply
Features
|
Specification 1
MODEL | QP-150-3A | QP-150-3B | QP-150-3C | ||||||||||
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | |
DC VOLTAGE | 5V | 3.3V | 12V | -5V | 5V | 3.3V | 12V | -12V | 5V | 3.3V | 15V | -15V | |
RATED CURRENT | 10A | 10A | 5A | 0.6A | 10A | 10A | 5A | 0.6A | 10A | 10A | 4A | 0.6A | |
CURRENT RANGE | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | |
RATED POWER (max.) | 146W | 150.2W | 152W | ||||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | ||||||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | +8,-6% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | |
SETUP, RISE TIME | 800ms, 50ms/230VAC 1800ms, 50ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 24ms/230VAC 24ms/115VAC at full load | ||||||||||||
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||||||||
INPUT | EFFICIENCY (Typ.) | 73% | 75% | 74% | |||||||||
AC CURRENT (Typ.) | 2.5A/115VAC 1.2A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START ≦40A/230V | ||||||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE | CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V | ||||||||||||
Protection type : Shutdown o/p voltage, re-power on to recover | |||||||||||||
OVER TEMPERATURE(OPTION) | Shutdown o/p voltage, recovers automatically after temperature goes down | ||||||||||||
WORKING TEMP. | -10 ~ +60℃ (Refer to "Derating Curve") | ||||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -20 ~ +85℃ , 10 ~ 95% RH non-condensing | |||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0~50℃) | ||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes | ||||||||||||
SAFETY STANDARDS | UL60950-1,TUV BS EN/EN62368-1, EACTPTC 004 approved | ||||||||||||
SAFETY & | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||||
EMC | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||||
(Note 4) | EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EACTPTC 020 | |||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EACTPTC 020 | ||||||||||||
MTBF | 1763.3K hrs min. Telcordia SR-332 (Bellcore) ; 262.6K hrs min. MIL-HDBK-217F (25℃) | ||||||||||||
OTHERS | DIMENSION | 199*99*50mm (L*W*H) | |||||||||||
PACKING | 0.93Kg; 20pcs/19.6Kg/1.21CUFT | ||||||||||||
NOTE | 1. All parameters NoT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMl testing of component power supplies.” 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). |
Specification 1
MODEL | QP-150-3D | QP-150D | QP-150F | ||||||||||
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | |
DC VOLTAGE | 5V | 3.3V | 24V | -12V | 5V | 12V | 24V | -12V | 5V | 15V | 24V | -15V | |
RATED CURRENT | 10A | 10A | 2.5A | 0.6A | 10A | 4A | 2A | 0.6A | 10A | 3A | 2A | 0.6A | |
CURRENT RANGE | 3 ~ 15A | 0 ~ 15A | 0.3 ~ 3A | 0 ~ 1A | 3 ~ 15A | 0 ~ 5A | 0.4 ~ 3A | 0 ~ 1A | 3 ~ 15A | 0 ~ 5A | 0.4 ~ 3A | 0 ~ 1A | |
RATED POWER (max.) | 150.2W | 153.2W | 152W | ||||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 150mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V | CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V | ||||||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | ±6.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | |
SETUP, RISE TIME | 800ms, 50ms/230VAC 1800ms, 50ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 24ms/230VAC 24ms/115VAC at full load | ||||||||||||
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||||||||
INPUT | EFFICIENCY (Typ.) | 76% | 78% | 78% | |||||||||
AC CURRENT (Typ.) | 2.5A/115VAC 1.2A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START ≦40A/230V | ||||||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE | CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V | CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V | CH1:5.75 ~ 6.75V CH2:17.25 ~ 20.25V | ||||||||||
Protection type : Shutdown o/p voltage, re-power on to recover | |||||||||||||
OVER TEMPERATURE(OPTION) | Shutdown o/p voltage, recovers automatically after temperature goes down | ||||||||||||
WORKING TEMP. | -10 ~ +60℃ (Refer to "Derating Curve") | ||||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -20 ~ +85℃ , 10 ~ 95% RH non-condensing | |||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0~50℃) | ||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes | ||||||||||||
SAFETY STANDARDS | UL60950-1,TUV BS EN/EN62368-1, EACTPTC 004 approved | ||||||||||||
SAFETY & | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||||
EMC | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||||
(Note 4) | EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EACTPTC 020 | |||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EACTPTC 020 | ||||||||||||
MTBF | 1763.3K hrs min. Telcordia SR-332 (Bellcore) ; 262.6K hrs min. MIL-HDBK-217F (25℃) | ||||||||||||
OTHERS | DIMENSION | 199*99*50mm (L*W*H) | |||||||||||
PACKING | 0.93Kg; 20pcs/19.6Kg/1.21CUFT | ||||||||||||
NOTE | 1. All parameters NoT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMl testing of component power supplies.” 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). |
QP - 150B,C series Specification
MODEL | QP-150B | QP-150C | |||||||
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | |
DC VOLTAGE | 5V | 12V | -12V | -5V | 5V | 15V | -15V | -5V | |
RATED CURRENT | 15A | 4A | 2A | 0.6A | 15A | 3A | 2A | 0.6A | |
CURRENT RANGE | 3 ~ 15A | 0.4 ~ 5A | 0.3 ~ 2A | 0 ~ 1A | 3 ~ 15A | 0.4 ~ 4A | 0.3 ~ 2A | 0 ~ 1A | |
RATED POWER (max.) | 150W | 153W | |||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | |
OUTPUT | VOLTAGE ADJ. RANGE | CH1:4.75 ~ 5.5V | CH1:4.75 ~ 5.5V | ||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±6.0% | +10,-6% | ±5.0% | ±3.0% | +6,-10% | ±8.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±2.0% | ±2.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±6.0% | ±6.0% | ±2.0% | ±2.0% | ±6.0% | ±6.0% | ±2.0% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC 2200ms, 50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 24ms at full load | ||||||||
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||||
INPUT | EFFICIENCY (Typ.) | 76% | 77% | ||||||
AC CURRENT (Typ.) | 2.5A/115VAC 1.2A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | COLD START ≦40A | ||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | CH1:5.75 ~ 6.75V | ||||||||
Protection type : Shutdown o/p voltage, re-power on to recover | |||||||||
OVER TEMPERATURE(OPTION) | Shutdown o/p voltage, recovers automatically after temperature goes down | ||||||||
WORKING TEMP. | -10 ~ +60℃ (Refer to "Derating Curve") | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -20 ~ +85℃ , 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0~50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes | ||||||||
SAFETY STANDARDS | UL60950-1,TUV BS EN/EN62368-1, EACTPTC 004 approved | ||||||||
SAFETY & | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||
EMC | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
(Note 4) | EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EACTPTC 020 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EACTPTC 020 | ||||||||
MTBF | 1763.3K hrs min. Telcordia SR-332 (Bellcore) ; 262.6K hrs min. MIL-HDBK-217F (25℃) | ||||||||
OTHERS | DIMENSION | 199*99*50mm (L*W*H) | |||||||
PACKING | 1.1Kg; 20pcs/22Kg/1.21CUFT | ||||||||
NOTE | 1. All parameters NoT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMl testing of component power supplies.” 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). |