Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Testermeter- JDG-Z Overhead live line fault indicator, fault passage indicator(FPI),Permanent Fault,Transient Fault,Earth Fault
Characteristic:
The shell using high strength and high transparency aeronautical material Fully Fashioned, and treated with nanotechnology, better perspectivity. resist filth, anti-aging, without maintenance, long service life. Built-in high performance lithium battery, Service life can reach more than eight years. The circuit board using special chip and MCU etc imported components. Theshell made from aeronautical material and nano materials. Theclamp with nickel plating process, best magnetic conductivity, Install and Remove with Electricity. Fault indication turn card with strong visual,it can clear instructions with light in the night, and the color not fade under sun ultraviolet light for a long time.
|
Function and Benefit
Indicate the fault line and fault point quickly, lessen the blackout area; Shorten troubleshooting time,improving electricity and power supply reliability; Accurately indicate the instant fault, which is conducive to rule out the power supply problems; Providing technical means for find the hidden permanent fault point; Shorten the search time to find the fault point, reduce the labor intensity of line patrol person; Defining the responsibility of the fault area and responsible people; Avoiding traditional multiple switch out,switch on,line patrol to the effects of power equipment. |
Technical Parameter
Parameter Items | Parameter Name | Parameter Details |
Electrical Parameter | Short circuit fault action current | 100A (Default , Can be set before delivery) |
Earth fault action current | 20A (The default injection method of grounding , Can be set before delivery) | |
Applicable line voltage | 6 ~ 36 kV | |
Applicable line current | 5~700A (Default) | |
Applicable power frequency | 50Hz/60Hz (According customer’s request) | |
Maximum short circuit current | 25kA/4s | |
Short circuit recognition time | 0.02~5s | |
Load measurement accuracy | ±3% | |
Power supply mode | 3.6V 2.4A Lithium battery + Self-charging from the cable(The line current ≥20A) | |
Static power loss | ≤7μA | |
Action power loss | < 20 mA | |
Minimum activate current | Insulated cable ≥10A Bare cable ≥0A | |
Auto reset mode | Time reset:4,8,12,24,36,48,72 Hours (Can be set before delivery, Default 12H) Auto reset after the power line recover | |
Action times | ≥5000 Times | |
Continuous flash time | ≥3000H | |
Indication | Red flag+ red LED flash | |
Engineering Parameter | Visibility angle | 360° 50 m day time, 300 m night time |
Flash time interval | Short circuit one time per 3s±10% Earth fault two times per 3s±10% | |
Ambient temperature | -40 ℃~ +85 ℃ | |
Relative humidity | ≤95% | |
Applicable wire diameter | 16mm~40mm | |
Maximum wind speed | ≤40m/s | |
Applicable altitude | ≤5000m | |
Fault alarm accuracy | ≥95% | |
Protection class | IP68 | |
Working life | ≥10 Years | |
MTBF | 60000 H | |
Weight | 500g ±10% | |
Dimensions | Ф75mm* 145mm |