China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator
Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator

Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator

2025-02-23 12:08:16  

DO30B-2 Single Phase AC DC Standard Source Power Supply Device

  • Main Feature :
  • Serial No. : Zoe682
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Testermeter- DO30B-2 Single Phase AC DC Standard Source Power Supply Device, multi-function factory price multimeter and clamp meter calibrator

 

The HZJD8001 multifunctional calibrator is suitable for verifying and calibrating various ammeters, voltmeters, and ohmmeters with an accuracy level below 0.2. It can also be used as a high-stability test power supply in accordance with the JJF 1587 - 2016 Calibration Specification for Digital Multimeters. This calibrator can be used in conjunction with high-precision standard meters to calibrate ammeters, voltmeters, and ohmmeters with an accuracy level above 0.2. It has two amplitude adjustment methods: analog adjustment (potentiometer) and digital adjustment (keyboard). It can also calibrate clamp meters, meeting the requirements of the JJF 1075 - 2015 Calibration Specification for Clamp Meters.


 Main Functions

1. It features a 5 1/2 - digit LED digital display output, which can be presented in two ways: actual value or percentage.

2. The AC/DC current output range is: 0 ~ 100μA ~ 500μA ~ 2mA ~ 5mA ~ 20mA ~ 50mA ~ 200mA ~ 500mA ~ 2A ~ 5A ~ 20A.

3. The AC and DC voltage output range is: 0 ~ 200mV ~ 1V ~ 2V ~ 5V ~ 10V ~ 20V ~ 50V ~ 100V ~ 200V ~ 500V ~ 1000V. There are three AC frequencies available: 50Hz, 60Hz, and 400Hz.

4. It has automatic protection against output overload and supports manual reset.

5. Each voltage and current output can withstand a 10% overload.

6. Clamp meter measurement: Equipped with a standard coil, it can measure AC 0 ~ 750A (some meters can measure over 1000A); DC 0 ~ 1000A with an error of ±0.3%.

Main Technical Specifications

1. Stability: DC 0.01% of full capacity/2 minutes; AC 0.03% of full load/2 minutes.

2. AC distortion: 0.5%.

3. DC ripple coefficient: 0.1%.

4. Output frequency and accuracy: 50Hz, 60Hz, 400Hz with an accuracy of 1%.

5. Output voltage and current range and accuracy (at 23℃±2℃, when the output value is greater than 10% of the range).

6. Power consumption: AC power supply voltage 220V±10%, frequency 50Hz±1Hz; power 180 VA.

7. Operating environment: The operating environment temperature is 5℃~35℃, and the relative humidity is not more than 80%.

8. Operating time: Continuous.

9. Dimensions: 135×480×420 mm³.

10. Weight: Approximately 16 kg.

Output Item

Output Range

Rated Output

Maximum Output

Accuracy

AC/DC Voltage

0 ~ 200mV

10mA

30mA

DC: ±(Reading × 0.05% + Full Scale × 0.02%) ± 0.02mV
AC: ±(Reading × 0.07% + Full Scale × 0.03%) ± 0.04mV


0 ~ 2V

20mA

60mA

The same as above


0 ~ 5V ~ 10V ~ 20V

40mA

100mA

The same as above


0 ~ 200V ~ 500V

20mA

60mA

The same as above


0 ~ 1000V

10mA

30mA

The same as above

AC/DC Current

0 ~ 100μA ~ 500μA
~ 2mA ~ 5mA
~ 20mA ~ 50mA

DC: 3V
AC: 36V

-

DC: ±(Reading × 0.07% + Full Scale × 0.03%)
AC: ±(Reading × 0.07% + Full Scale × 0.03%)
Accuracy below 2mA not tested


0 ~ 200mA
~ 500mA

DC: 3V
AC: 12V

-

The same as above


0 ~ 2A ~ 5A ~ 20A

2V

-

The same as above

Standard Resistor

10, 24, 50, 100, 240, 500 (Ω)
1, 2.4, 5, 10, 24 (KΩ) with ×1K and ×1 magnification gears (i.e., 10KΩ ~ 24MΩ)

0.25W

-

±0.2% + 20mΩ