  • Main Feature : 1000V Maximum Input Voltage, High-Voltage Battery Tester for Measuring EV and PHEV Battery Packs
  • Serial No. :
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Product Introduction

Hioki benchtop battery testers support simultaneous high-speed measurement of the internal resistance and battery voltage of EV and PHEV battery packs. The BT3564 Battery HiTester can measure pack voltage and total resistance, as well as bus bar resistance up to 1000V.

Main Features

●  Measure high-voltage battery packs up to 1000 V

● Production line testing of high-voltage battery packs for EV, PHEV

● 0.1 μΩ to 3000 Ω internal resistance range (pack total resistance, bus bar resistance)

● Spark discharge reduction function

● Analog output function

● Optional measurement probe available for 1000 V and high-voltage battery packs

Basic specifications

Accuracy guaranteed: 1 year

Max. applied
measurement voltage
± 1000 VDC rated input voltage
± 1000 VDC max. rated voltage to earth
Resistance measurement ranges3 mΩ (max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3 kΩ (max. display 3.1000 kΩ, resolution 0.1 Ω), 7 ranges
Accuracy: ±0.5 % rdg. ±5 dgt. (30 mΩ to 3 kΩ range), ±0.5 % rdg. ±10 dgt. (3 mΩ range)
Testing source frequency: 1 kHz ±0.2 Hz, testing current: 100 mA (3 mΩ range) to 10 μA (3.000 kΩ range)
Open terminal Voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3.000 kΩ range)
Voltage measurement ranges10 V DC (resolution: 10 µV) to 1000V DC (resolution: 1 m V), 3 ranges
Accuracy: ±0.01 % rdg. ±3 dgt.
Display31000 full digits (resistance), 999999 full digits (voltage, 1000 V range: 999999 or 110000), LED
Sampling timeFAST: 12 ms, MEDIUM: 35 ms, SLOW: 253 ms
(Typ., sampling time depends on supply frequency settings and function.)
Total measurement timeResponse time + sampling time (Response time for both resistance and voltage are reference value of about 700 ms, depends on measurement object.)
Comparator functionsJudgment result: Hi/IN/Lo (resistance and voltage judged independently)
Setting: Upper and lower limit, Deviation (%) from reference value
Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results.
Result display, beeper, or external I/O output (open-collector, 35 V, 50 mA DC max.)
Analog outputMeasured resistance (displayed value, from 0 to 3.1 V DC)
InterfacesExternal I/O, RS-232C, Printer (RS-232C), GP-IB
Power supply100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass215 mm (8.46 in) W × 80 mm (3.29 in) H × 295 mm (12.95 in) D, 2.4 kg (84.7 oz)
Included accessoriesInstruction manual ×1, Power cord ×1 , Operating Precautions ×1