Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
TesterMeter-Rotronic HydroPalm HP32 with HC2A-IC015 Probe VERSATILE HANDHELD INSTRUMENT FOR HUMIDITY AND TEMPERATURE
Overview
The HygroPalm HP32 is a versatile handheld instrument compatible with all HC2A and HC2 Rotronic probes, it is able to perform spot measurements and logging of relative humidity, temperature and psychrometric parameters. Simply connect it to the probe input on the top. |
Advantages of the HygroPalm handheld device
1,Relative humidity, temperature and psychrometric calculations 2,Graphical display for graphs and up to 4 values 3,Freely settable visual and audible alarms on every value 4,64’000 data points memory for time programmable interval logging 5,Long lasting battery (up to 48 h when logging every 30 s) |
Applications
1,Field inspection and spot checks in HVAC 2,Building Management Systems 3,Agriculture and Food industry 4,Pharmaceutical Industry |
The HygroPalm HP32 handheld instrument is compatible with
1,All HC2 and HC2A probes (except HC2-LDP) 2,HW4 Software |
Scope of delivery
1,HygroPalm HP32 (without probe) 2,Soft Case 3,Micro-USB Cable (computer connection and battery charging) 4,HW4 LITE license key (3 instruments connected max) |
Possible probes for the HP32
Standard and High Precision probes: 1,Accuracy (Standard): ±0.8 %RH, ±0.1 K at 10…30 °C 2,Accuracy (High Precision): ±0.5 %RH at 10...90 %RH, ±0.1 K at 10…30 °C |
High temperature handheld probe: 1,Accuracy: ±0.8 %RH, ±0.2 K at 10...30 °C 2,Application range: -100...200 °C, 0...100 %RH 3,Long-term stability: < 1 %RH / year |
Insertion probes: 1,Accuracy: ±0.8/1.5 %RH, ±0.1/0.3 K at 10…30 °C 2,Application range: -40…85 °C/0…100 %RH 3,Long-term stability: < 1 %RH / year |
Technical Parameters
Dimensions | 160 x 63 x 30 mm |
---|---|
Psychrometric calculations | Dew / Frost point (Dp /Fp) Wet bulb temperature (Tw) Enthalpy (H) Vapor concentration (Dv) Specific humidity (Q) Mixing ratio by weight (R) Vapor pressure (E) Saturation vapor pressure (Ew) Saturation vapor density (SVD) |
IP protection rating | IP65 |
Communication interfaces | Micro USB |
Weight | 185 g |
Housing | ABS, TPR |
Device type | Handheld device |
Storage and transport conditions | -10…45°C / 10…90%RH |
Parameters | Relative humidity and temperature |
Accuracy | Depends on the probe |
Battery | Lithium Polymer, 3,7V, 1000 mAh (integrated) 48h – Logging every 30s, screen off 10h – Screen always on |
Logging interval | 1 s…24 h |
Storage capacity | 8x8000 data points |
Display refresh rate | 1 s (typical) |
Probes | All HC2A and HC2 probes |
Functions | Spot measurements Time programmable interval logging MIN / MAX / AVG |
Calculation method | WMO Standard |