Contact US For Quotation | Email:464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
TesterMeter-MIK-R200T(1,2,4,6 Channels Optional) COLOR PAPERLESS RECORDER,Temperature recorder, temperature and humidity recorder, pressure, current, voltage, and electricity meter
Overview
Thank you for buying our products. This specification describes the information required for product use, including product identification, storage, installation, commissioning, electrical connections, operation settings and troubleshooting. This product is an industrial paperless recorder with 6 channels universal input. It can receive signals such as current, voltage, thermocouple and thermal resistance, display them in real time and store the data in the internal electronic memory. The device can quickly transfer the historical data through the USB interface. |
Features
1,6-Channel input, 6-Channel alarm |
2,2-Loop transmitter, 2-Loop 24VDC output |
3, 4-inch 800X480 pixels color LCD display |
4,128Mb Memory 900,000 historical records |
5, 256 records of alarm record/power-down/log |
6,High speed USB Interface |
Specifications
Category | Signal | Measuring range | Accuracy /25℃ | |
Current | 4-20mA | 4.00~20.00mA | ±0.2% | |
0-20mA | 0.00~20.00mA | ±0.2% | ||
0-10mA | 0.00~10.00mA | ±0.2% | ||
Voltage mV | 20mV | 0.00~20.00mV | ±0.2% | |
100mV | 0.00~100.00mV | ±0.2% | ||
Voltage V | 0-5V | 0.000~5.000V | ±0.2% | |
0-10V | 0.00~10.00V | ±0.2% | ||
1-5V | 1.000~5.000V | ±0.2% | ||
TC | Isolated | Not Isolated | ||
K | -200~1372℃ | TCJ ~1372℃ | ±2℃ | |
S | -50~1768℃ | TCJ ~1768℃ | ±3℃ | |
B | 250~1820℃ | 250~1820℃ | ±3℃ | |
J | -210~1000℃ | TCJ ~1000℃ | ±2℃ | |
R | -50~1768℃ | TCJ ~1768℃ | ±3℃ | |
N | -200~1300℃ | TCJ ~1300℃ | ±3℃ | |
T | -200~400℃ | TCJ ~400℃ | ±2℃ | |
E | -200~1000℃ | TCJ ~1000℃ | ±2℃ | |
WRe3-25 | 0~2315℃ | TCJ ~2315℃ | ±2℃ | |
WRe5-26 | 0~2310℃ | TCJ ~2310℃ | ±2℃ | |
F1 | 700~2000℃ | 700~2000℃ | ±2℃ | |
F2 | 700~2000℃ | 700~2000℃ | ±2℃ | |
RTD | Pt100 | -200.0~650.0℃ | ±0.5℃ | |
Cu50 | -50.0~140.0℃ | ±0.5℃ | ||
Cu53 | -50.0~150.0℃ | ±0.5℃ | ||
Cu100 | -50.0~150.0℃ | ±0.5℃ | ||
Fr | Fr | 0~10000Hz | 1Hz |
Project | Specification |
Dimensions | Panel 160*80mm, opening 152*76mm |
Weight | 450 grams |
Installation mode | Panel-mounting, indoor |
Channels | 6-channel universal analog input |
Accuracy | 0.2% F.S. |
Sampling period | 1second |
EFT | Not isolated: Power EFT 1000V, Signal EFT 500V Isolated: Power EFT 2000V, Signal EFT 1000V |
ESD | Contact discharge 4000V Air discharge 8000V |
Limit voltage | Between input terminal: 400V; Between protect earth with input terminal: 1000V. |
Insulation resistance | ≥500MΩ |
24VDC Output | 2-Loop 24 VDC±10%, 30mA per loop |
Alarm relay | 6 relays, 250VAC 3A, 30VDC 3A (Normal open) |
Analog output | 2-Loop 4-20mA output Load < 750Ω Accuracy 0.2% F.S. |
Power supply | AC 100~240 VAC 50Hz / DC 24VDC+10% 10W |
Preheating time | 30 minutes after power-on |
Work environment | Temperature: -10~60°C humidity: 0~85% RH (no condensation) |
LCD screen | 4 inch color LCD screen, 800*480 pixels |
Record Interval | 1s/2s/5s/10s/15s/30s/1m/2m/5m/10m/30m/1h |
Data memory | 128Mb, 900,000 records; 10days record duration with 1s recording interval, The other recording intervals have the same linear ratio. |
Other records | 256 alarm records, 256 power-down records, 256 operation logs |
RS485 | Standard Modbus-RTU Protocol |
Micro printer, 3.3V TTL | |
USB | USB2.0 |