China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Testermeter- F-ACR Automatic Circuit Recloser
Testermeter- F-ACR Automatic Circuit Recloser
Testermeter- F-ACR Automatic Circuit Recloser
Testermeter- F-ACR Automatic Circuit Recloser

Testermeter- F-ACR Automatic Circuit Recloser

2025-03-08 22:47:22   45139

F-ACR Automatic Circuit Recloser

  • Main Feature :
  • Serial No. : Zoe713
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Testermeter- F-ACR Automatic Circuit Recloser

 

Automatic Circuit Reclosers (ACRs) are outdoor intelligent switch applied in the filed of distribution automation, usually mounted on outgoing line side of substation, tie points of ring network, trunk line of distribution grid, or at the head of important feeder lines, with short-circuit current breaking and making ability, completed with feeder terminal unit (FTU), which can realize multiple reclosing function. When a short-circuit fault occurs on the line, Automatic Circuit Recloser implements cycling operation according to the sequence and time interval. When a permanent fault occurs, after implementing preset cycling operation sequence, Automatic Circuit Recloser is keep opening and block to close to isolate the faulted section. When the fault is removed, a manual reset is needed to release blocking status and implement close operation. When a transient fault occurs, the subsequent opening and closing operations are terminated in the cyclic opening and closing operation, regardless of which reclosing is successful, and initial setting status is restored after a certain delay time.


Our company latest development xx series Automatic Circuit Recloser s, cover 15KV, 27KV, 38KV voltage level, reach 1200A maximum rated current, meet IEC62271-111 and IEEE C37.60 international standards.


 

Technical Description:

Parameter/Type

15kV ACR

27kV ACR

38kV ACR

Rated Voltage(kV)

2.4-14.4

24.9

34.5

Maximum Voltage(kV)

15.5

27

38

Rated Power Frequency withstand Voltage(kV)

50/60 

60/70 

70/80

Rated lightning impulse withstand Voltage(kV) 

110/125 

125/150 

150/170

Rated Normal Current(A) 

630/800/1000

630/800/1000 

630/800/1000

Rated Short Circuit Breaking Current(kA) 

12.5/16

12.5/16 

12.5/16

Rated Short Circuit Making Current(kA)

31.5/40

31.5/40

31.5/40

Rated Short-time withstand Current(kA/s) 

12.5/3 16/3

12.5/3 16/3

12.5/3 16/3

Arc Extinguishing Medium 

Vacuum 

Vacuum

Vacuum

Insulation Medium

Solid

Solid

Solid

Operation Mechanism 

Magnetic Actuator 

Magnetic Actuator 

Magnetic Actuator

Bushing 

Epoxy or Silicon Rubber 

Epoxy or Silicon Rubber 

Epoxy or Silicon Rubber

Mechanical endurance CO 

10000

10000

10000

Creepage Distance(mm) 

640 

960 

1288

Pollution Level 

IV (31mm/kV)

IV (31mm/kV) 

IV (31mm/kV) 

Ambient air temperature range()

-40..+70 

-40..+70 

-40..+70 

Altitude(m) 

2000

2000

2000

Degree of Protection

IP67

IP67

IP67

Reference Standard 

IEC62271-111,IEEE C37 60 

IEC62271-111,IEEE C37 60 

IEC62271-111,IEEE C37 60

 1664263265551626.jpg



Telephone
Email
Map
QQ Chat
× -

Online Chat

Whatsapp:
+86-18620373879