ETCR050-0mA ~ 600A AC, φ50mm R Type Clamp Current Sensor

  • Main Feature : 1. AC large current, high harmonic current, phase, electric energy, power, power factor and other industrial electricity consumption and electricity metering detection. 2. Input current range: 0mA ~ 600A 3. Output signal: mA/A;mV/A;1A;5A ; 4. Frequency: 10Hz~100kHz; 5. Accuracy Class :0.5
  • Serial No. :
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

INTRODUCTION

AC large current, high harmonic current, phase, electric energy, power, power factor and other industrial electricity consumption and electricity metering detection.

Apply for industrial control device, oscilloscope, harmonic analyzer, path analyzer, double clamp earth resistance tester, cable fault tester, power quality analyzer.

MAIN FEATURES

  1. Clamp structure, no need to interrupt the power supply and disconnect the circuit in testing, easy to operate, fast, safe and reliable.

  2. Input current range: 0mA ~ 600A, output signal: mA/A;mV/A;1A;

  3. Output interface: BNC plug/ 4.0mm double banana plug/φ3.5mm Audio plug/Aviation plug(optional), wire length: 2m

  4. CT Size: φ50mm.

  5. Sensor Dimensions: 200mmX100mmX39mm

  6. Weight:550g

  7. Safety Level:CAT III 600V

  8. Certificate:ROHS

  9. Working temperature: -15°C~60°C

  10. The input current, output signal and output interface of the sensor can be customized according to customer requirements.

SPECIFICATION

Model

Input Current

Output Signal

Frequency

Secondardy Load

Accuracy Class

Series

TesterMeter-ETCR050

0mA~300A

100mA

10Hz~100kHz

0~10A≤500Ω

0~100A≤50Ω

0~1000A≤5Ω

0.5

L0501

0mA~400A

200mA

0.5

L0502

0mA~600A

600mA

0.5

L0503

1A~600A

1mV/A

≥100kΩ

1.0

Y0501

TesterMeter-ETCR050A

300A

1A

40Hz~1kHz

≤2.5VA

0.5

L0520

500A

1A

≤2.5VA

0.5

L0521

600A

1A

≤2.5VA

0.5

L0522

300A

5A

≤5VA

1.0

L0523

500A

5A

≤5VA

0.5

L0524

600A

5A

≤5VA

0.5

L0525