Contact Us for Quotation | Email: mewoi008@mewoi.com | Whatsapp:+8619928420370 |
Testermeter-N1008A(800Vp-p,50MHz) differential probe 1% accuracy
INTRODUCTION
Testermeter-N1008A, Small voltage special, built-in automatic zero, test accuracy 1%, can be compatible with any brand oscilloscope. | ||
Technical Specification
Model | Testermeter-N1008A |
Bandwidth(-3dB) | DC-50MHz |
Attenuation Ratio | 1:100/10 |
Accuracy | ±1% |
Impedance | 4MΩ//1.3pF |
Rise time | 7ns |
-Output(into 50kΩ load) | 7V |
-Offset(typical) | <±5mV |
Oscilloscope input impedance | 1MΩ |
CMRR | -80dB@60Hz,-50dB@100kHz |
Input AC Vp-p | 800V@1/100 80V@1/10 |
Input DC Voltage | 400V@1/100 40V@1/10 |
Size | 165*69*26 mm |
Selection Guide
Model | Testermeter-N1008A | Testermeter-N1008B | Testermeter-N1000A |
Bandwidth(-3dB) | DC-5MHz | DC-100MHz | DC-50MHz |
Attenuation Ratio | 1:100/10 | 1:100/10 | 1:1000/10 |
Accuracy | ±1% | ||
Impedance | 4MΩ/1.3pF | 4MΩ/1.3pF | 8MΩ/1pF |
Rise time | 7ns | 3.5ns | 7ns |
Output(into 50%Ω load) | 7V | ||
-Offset(typical) | <±5mV | ||
Oscilloscope input impedance | 10MΩ | ||
CMRR(Typical) | -80dB@60Hz,-50dB@100kHz | ||
Input AC Vp-p | 800V@1/100 80V@1/10 | 8000V@1/100 80V@1/10 | 1500V@1/1000 150V@1/100 |
Input DC Voltage | 400V@1/100 40V@1/10 | 400V@1/100 40V@1/10 | 750V@1/1000 75V@1/100 |
Size | 165x69x26mm | ||
Model | Testermeter-N1015A | Testermeter-N1030A | Testermeter-N1030B |
Bandwidth(-3dB) | DC-100MHz | DC-50MHz | DC-100MHz |
Attenuation Ratio | 1:100/10 | ||
Accuracy | ±1% | ||
Impedance | 8MΩ/1pF | ||
Rise time | 3.5ns | 7ns | 3.5ns |
Output(into 50%Ω load) | 7V | ||
-Offset(typical) | <±5mV | ||
Oscilloscope input impedance | 1MΩ | ||
CMRR(Typical) | -80dB@60Hz,-50dB@100kHz | ||
Input AC Vp-p | 1500V@1/1000 150V@1/100 | 3000V@1/1000 300V@1/100 | 3000V@1/1000 300V@1/100 |
Input DC Voltage | 750V@1/1000 75V@1/100 | 1500V@1/1000 150V@1/100 | 1500V@1/1000 150V@1/100 |
Size | 165x69x26mm |