Contact Us for Quotation | Email:464560351@qq.com | Whatsapp: +8618620373879 |
Principle Introduction
The sensing material of TesterMeter-MIX1006 is tin dioxide SnO2, which has low conductivity in clean air. When the combustible/LPG gas exists, the conductivity of the sensor will be raise according to the gas concentration goes up. Through a simple circuit, to convert the changes of conductivity to correspond to the gas concentration. TesterMeter-MIX1006 Combustible Gas Sensor(LPG) has high sensitivity to LPG (propane). The sensor can work in high temperature. It is low cost sensor and can be used in different applications. |
Features
* High sensitivity to wide range of combustible gas * High sensitivity to methane * Long life and low cost * High ant seismic |
Application
* Domestic gas leakage detectors * Portable gas detectors |
Technical Parameters
Item | Specification |
Target Gas | LPG |
Measurement Range | 300~10000ppm(CH4, C3H8) |
Heater Voltage(VH) | 5.0V±0.1V AC or DC |
Load Resistance(RL) | Adjustable |
Loop Voltage | ≤24V DC |
Heater Resistance(RH) | 29Ω±3Ω(Room temperature) |
Heater Power Consumption(PH) | ≤950mW |
Sensitivity | Rs(in air)/Rs(2000ppm C3H8)≥ 5 |
Output In Target Gas | 2.5~4.0V(in 2000ppm C3H8) |
Testing Condition | 20℃±2℃;55%±5%RH |
Oxygen concentration in used place | 21%, no less than 18% If used in low oxygen concentration, pleasure contact for detail |
Life Expectancy | 10 years |