Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Xtester-TXF1250
Xtester-TXF1250 high- voltage power supply is an X-ray generator module specially designed for OEM applications, with a voltage output of up to 160kV and a power of 1200W. The power supply has a universal input, a small package size and three standard digital interfaces, which can be more simplified and integrated into your X-ray analysis system. The whole series of models can be used in any X-ray tube design of suspended filament (negative high voltage polarity) or grounding filament (positive high voltage polarity). The control circuit based on DSP enables the power supply to provide excellent emission current regulation and excellent stability. Typical Application:Blood irradiation, nondestructive testing, crystal testing,electroplating measurement,diamond testing, mineral analysis,X-ray fluorescence, X-ray diffraction, plastic sorting. |
FEATURES
|
PRODUCT SPECIFICATIONS
Input voltage Input power factor correction AC100-240V ±10%;300W power supply, 47-63Hz, 4.6A. AC200-240V ±10% 600W power supply, 47-63Hz, 4.3A. 1200W power supply, 47-63Hz, 8.2A. Output voltage 8Models - 20kV, 30kV, 40kV, 50kV, 60kV, 70kV, 75kV, 100kVAnd 160kV. Output polarity Negative polarity - used for suspended filament X-ray tube Positive polarity - used for grounding filament X-ray tubes Power 300W, 600W, 1200W. Customizable Output voltage regulation Within the specified input voltage range, ≤ 0.01% of the rated output voltage. Full load change, ≤ 0.01% of the rated output voltage. Emission current regulation Within the specified input voltage range, ≤ 0.01% of the rated output current. When the rated output voltage changes from 30% to 100%, ≤ 0.01% of the rated output current. When kV < 30% of the full range output, the filament is disabled. Ripple Under rated output conditions, it is better than 1% rms (0.1% rms optional). Stability After 2 hours of startup, it is better than 25ppm/hour. Temperature coefficient Voltage and current are better than50ppm/℃. Environment Temperature range Operating temperature 0 C to 40 C Storage temperature -40 C to 85 C Humidity 20% to 85% relative humidity, no condensation. Filament configuration Closed-loop emission control adjusts the filament setting to provide the desired X-ray tube emission current. Two types are available suspension filament (AC output is referenced by negative output voltage) and grounding filament (DC output is referenced by ground). Output Control interface Local interface Adjust the filament limit and preheating level through the potentiometer. Remote interface Standard USB, Ethernet and RS232. All digital monitoring is a 2% accuracy specification. Control software Provide an example of Windows graphical user interface. High voltage enable Hardware-based, dry contact closure will enable the power supply to enter high- voltage mode. Monitoring signal The voltage and current monitoring signal are proportional, 0-10VDC is equal to 0-100% full range, and the accuracy is 1%. Cooling Forced ventilation. External dimensions 300/600W 120.65mm high, 152.4mm wide and 304.8mm deep. 1200W 120.65mm high, 304.8mm wide and 304.8mm deep. 160kV 226.7mm high, 482.6mm wide and 546.1mm deep. Weight 300/600W 7.5Kilogram 1200W 15Kilogram 160kV 70Kilogram Input power connector IEC320 with EMI filter Output connector It depends on the polarity choice. See the table and drawings. Other connector and pin allocation can be provided by customization. |