TesterMeter-Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system. |
Key features
|
Voltage inputs | |
Number of inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
Measurement category | 1000 V CAT III / 600 V CAT IV |
Maximum input voltage | 1000 V rms / 1000 V dc (1700 Vpk) |
Nominal voltage range | Wye and single phase: variable (50 V – 1000 V) Delta: Variable (100 V – 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V |
Input impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |
Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
Resolution | 24-bit synchronous sampling |
Sampling frequency | 80 kS/s at 50/60 Hz |
Scaling | 1:1, variable for use of potential transformers |
Voltage transients | |
Measurement range | ±8 kV |
Sampling rate | 1775: 1 MS/s 1777: 1 MS/s, 20 MS/s |
Bandwidth | DC to 1 MHz |
Trigger | Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz |
Resolution | 14-bit synchronous sampling |
Current inputs | ||
---|---|---|
Number of inputs | 4 inputs 3 phases and Neutral, range selected automatically to attached sensor | |
Range | AC | 1 A to 1500 A with i17XX-FLEX1500 12 1 A to 1500 A with i17XX-FLEX1500 24 3 A to 3000 A with i17XX-FLEX3000 24 6 A to 6000 A with i17XX-FLEX6000 36 40 mA to 40 A with clamp i40s-EL 4 A to 400 A with clamp i400s-EL |
DC | 20 A to 2000 A with 80i-2010-EL clamp | |
Bandwidth | DC to 30 kHz | |
Resolution | 24-bit synchronous sampling | |
Sampling frequency | 80 kS/s at 50/60 Hz | |
Scaling | 1:1, variable | |
Input voltage | Clamp: 50 mV / 500 mV rms; CF 2.8 Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4 all at nominal probe range | |
Input impedance | 11 kΩ |
Aux inputs | |
---|---|
Wired connection with 17XX-AUX adapter | |
Number of inputs | 2 |
Input range | Direct: 0 V dc to ± 10 V dc 0 V to 1000 V dc |
Input impedance | Direct: 2.92 MΩ |
Scale factor | Format: mx + b (gain and offset) user configurable |
Displayed units | User configurable (up to 8 characters, for example °C, psi, or m/s) |
Data acquisition voltage and current | |
---|---|
Input mains frequency | DC, 50/60 Hz 15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz) |
Topologies | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta |
Data storage | Fluke 1773/1775: 8 GB internal (expandable with microSD card) Fluke 1777: 32 GB microSD card (installed) |
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events. The number of possible logging sessions and logging period depends on user requirements |
Real time accuracy | Internal: 3 ppm (0.26 s per day, 8 s per month) NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC GPS: < 1 ms absolute to UTC |
parameter | range | Resolution | Intrinsic Accuracy at Reference Conditions % of Reading + % of Full Scale | |
Voltage | 1000 V | 0.1 V | 0.1 % of nominal voltage in accordance with IEC 61000-4-30 Class A1,2 ±(0.04 % + 0.004 %)3 | |
Voltage dips and swells | - | 0.1 V | 0.2 % of Vnom1,2 | |
Voltage transients | ±8 kVpk | - | ±5 % +0.25 %) | |
Voltage harmonics/interharmonics | 100 % | 0.1 % / 0.1 mV | ≥1 % Vnom1: ±2.5 % of rdg. <1 % Vnom1: ±0.025 Vnom | |
THD on voltage | 100 % | 0.1 % / 0.1 V | ±(2.5 % + 0.5 %) | |
Voltage distortions 2-9 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Voltage distortions 9-30 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Current (Rogowski clamp mode) | With iFlex 1500 A, i17XX-FLEX1500 24 | 150 A 1500 A | 0.01 % 0.1 A | ±(1 % + 0.02 %) |
With iFlex 3000 A, i17XX-FLEX3000 24 | 300 A 3000 A | 0.01 A 0.1 A | ±(1 % + 0.03 %) | |
With iFlex 6000 A, i17XX-FLEX6000 36 | 600 A 6000 A | 0.1 A 1 A | ±(1.5 % + 0.03 %) | |
With AC clamp 40 A, i40s-EL | 4 A 40 A | 0.001 A 0.01 A | ±(0.7 % + 0.02 %) | |
With AC clamp 400 A, i400s-EL | 40 A 400 A | 0.01 A 0.1 A | ±(2 % + 0.2 %) ±(0.7 % + 0.1 %) | |
With AC/DC clamp 2000 A, 80i-2010s-EL | 200 A 2000 A | 0.01 A 0.1 A | ±(0.8 % + 0.2 %) | |
Current min/max | 100 % | defined by accessory | x2 of intrinsic accuracy | |
Current harmonics/interharmonics | 100 % | 0.1 % / 0.01 A | ≥3 % Inom: ±2.5 % of rdg.4 <3 % Inom: ±0.15 % of Inom | |
THD on current | 100 % | 0.1 % | ±(2.5 % + 0.5 %) | |
Frequency | 42.5 Hz … 69 Hz | 0.001 Hz | ±0.01 Hz | |
Voltage unbalance | 100 % | 0.1 % | ±0.15 % | |
Current unbalance | 100 % | 0.1 % | ±0.15 % | |
Flicker Pinst, Pst, Plt | 0 to 20 | 0.01 | 5 % | |
Mains signaling voltage | Up to 3 kHz 0-15 % of Vnom | 0.1 V / 0.1 % | 1-3 % Vnom: ±0.15 % of Vnom 3-15 % Vnom: ±5 % of rdg. | |
AUX input | ±10 V | 0.1 mV | ±(0.2 % + 0.05 %) | |
1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin. 2 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3 3 Only for calibration laboratories 4 With iFlex 1500A, I17XX-FLEX1500 24 |