TD1880 Precision Multifunction Calibrator analog resistance

  • Main Feature :
  • Serial No. : Zoe374
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Testermeter- TD1880 Precision Multifunction Calibrator analog resistance

 

TD1880  is a multi-function calibrator with wide range and high accuracy, integrates AC/DC voltage and current standard source, can output excellent DC\AC voltage, DC\AC current, DC\AC power, phase, frequency, and analog resistance and capacitance etc. It's applied for calibrating 6.5 digits or less digital multimeters.


 

Summary TD1880 Precision Multifunction Calibrator

TD1880 Precision Multi-function Calibrator is a multi-function calibrator with wide range and high accuracy, integrates AC/DC voltage and current standard source, can output excellent DC\AC voltage, DC\AC current, DC\AC power, phase, frequency, and analog resistance and capacitance etc. Its applied for calibrating 6.5 digits or less digital multimeters.


 

Features of TD1880 Precision Multifunction Calibrator

DC voltage output: ± (0~1020 V)

 

DC current output: ± (0 ~ 20.5 A)

 

AC voltage output: 1mV ~ 1020 V

 

AC current output: 29 μA ~ 20.5 A

 

Sinusoidal wave frequency: 10 Hz ~ 500 kHz

 

Simulated DC resistance: 0 Ω ~ 1100 MΩ

 

2 MHz square wave frequency output

 

 Phase output

 

AC/DC power output

 

Simulated capacitance(optional)

 

8 kinds of thermocouple output and measurement (option)

 

6 kinds of thermal resistance output (option)

 

Clamp meter calibration (optional)

 

Calibrate AC\DC electrical measuring instruments

• DCV output: ± (0 ~ 1020 V)

• DCI output: ± (0 ~ 20.5 A)

• ACV output: 1 mV~1020 V,10 Hz ~ 500 kHz

• ACI output: 29 μA~ 20.5 A,10 Hz ~ 30 kHz

• RES output: 0 Ω ~ 1100 MΩ

• F output: 1 Hz ~ 2 MHz

• It is suitable for calibrating digital multimeters of 6.5 digits and below, DC voltmeters and DC resistance meters of Class 0.01 and below, DC ammeters and AC voltmeters of Class 0.05 and below, AC ammeters of Class 0.1 and below, and Class 0.01 and below The frequency meter.

 

Calibrate AC\DC power meters

Application: A virtual power standard source composed of independent output of AC and DC voltage ( DCV / ACV ) and AC and DC current ( DCI / ACI ) with adjustable phase, suitable for calibrating AC and DC power meters with conventional U-I measurement methods.

 

It is suitable for calibrating DC power meters of Class 0.05 and below, active power meters of Class 0.1 and below, reactive power meters, apparent power meters, power frequency phase meters, power factor meters, and power analyzers.

 

 

 