INTRODUCTION
TesterMeter801 series automatic insulating oil pressure tester is designed according to national standard GB507-86 and line standard, DL - 474-4-92, the relevant provisions of the DL/T596-1996, with a lot of field test and long-term unremitting efforts, carefully research and development of high accuracy, fully digital industrial equipment. In order to satisfy the needs of different users, this series of instruments can be divided in o single cup three cups and six cup type, etc. The instrument is simple, modelling is beautiful and easy. Adopt fully automatic digital computer control; the measurement is of high precision, strong anti-jamming capability, safe and reliable. |
INSTRUMENT CHARACTERISTICS
1,The instrument USES large capacity single-chip microcomputer control, stable and reliable in work. |
2. The device has wide scope of the watchdog circuit to prevent the death machine. |
3. Various operation options, the instrument program has gb507-1986, gb507-2002 two national standard methods and custom operation, can adapt to different user's various choices; |
4. The instrument oil cup is cast in a special glass, which eliminates the interference phenomenon such as oil leakage; |
5. The unique high voltage end sampling design of the instrument allows the test value to go directly in o A/D converter, avoiding the error caused by the simulation circuit and making the measurement results more accurate; |
6. The instrument has the function of flow, overpressure, short circuit, etc., and has the strong anti-interference ability and electromagnetic compatibility; |
7. Portable structure, easy to move, indoor and outdoor use is very convenient. |
TECHNICAL SPECIFICATION
Compliance | The TesterMeter801 device is in compliance with standard IEC 60156, China Standard GB507-1986、GB507-2002; DL429.9-91,DL/T846.7-2016,etc. |
Booster capacity | Booster capacity:1.5kVA |
Booster speed | 2.0kv/s, 3.0kv/s, optional Poor miss:0.2kV/s |
Output voltage | 0 ~ 80kv |
Power distortion factor | <1% |
Display mode | Large screen LCD character display |
The electrode spacing mm | Standard 2.5 mm |
Overall dimensions | (L*W*H)(430*350*370mm) |
Instrument weight | 26 kg |
WORKING CONDITIONS
The environment temperature | 0~40℃ |
Relative humidity | ≤ 85% |
Working power supply | AC 220V ± 20% |
Power frequency | 50 Hz ± 5 Hz |
Power consumption | <200 W |