Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro
Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro
Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro
Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro
Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro
Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro

Testermeter- SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro

2024-07-29 16:17:14  

SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro

  • Main Feature :
  • Serial No. : Zoe190
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-SKZ1052 differential scanning calorimetry dsc oxidation induction time OIT dsc calorimetro

DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature (Tg), melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).


Standards:

ISO/TR10837:1991,ASTM D3895-1998,ASTM E 967,ASTM E 968,ASTM E 793,ASTM D 3895, ASTM D 3417,ASTM D 3418, ISO 11357-6


Main Features:

1. The industrial-grade 7-inch touch screen displaysrichinformation.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy.The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communicationinterface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gasinput is added.
5. The softwareis simple andeasy to operate.


Specification

Temperature range

RT~ 550 ℃

Heating rate

0.1~80℃/min

Temperature resolution

0.001℃

Temperature fluctuations

±0.001℃

Temperature repeatability

±0.1℃

Constant temperature time

Program setting ≤24h

DSC range

0~±600mW

DSC noise

0.01μW

DSC resolution

0.01μW

DSC accuracy

0.01mW

Atmosphere control gas

Nitrogen, Oxygen (instrument switch automatically)

Gas flow rate

0-300mL/min

Gas pressure

0.2MPa

Control Mode

Rising temperature, constant temperature(full automatic)

Curve scanning

Rising scan

Gas flow control

Built-in digital flow meter & Software control, automatic

Display

24 bit 7 inches LCD touch screen display

Data interface

standard USB connector

Parameter standard

With standard material, with calibration function, the user may correct temperature and heat enthalpy

Software

operating software

Thermocouples

Total 3 sets of thermocouples for:
1). Test sample temperature
2). test furnace temperature,
3). Test internal ambient temperature

Cooling device

Air cool

Power

AC220V/50Hz