China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-MIX1005 Combustible Gas Sensor(CH4 & LPG)

TesterMeter-MIX1005 Combustible Gas Sensor(CH4 & LPG)

2023-07-06 15:25:19  

Target Gas: Combustible gas, LPG Range :300~10000ppm Application: Domestic gas leakage detectors,Portable gas detectors

  • Main Feature :
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

Principle Introduction

The sensing material of TesterMeter-MIX1005 is tin dioxide SnO2, which has low conductivity in clean air. When the combustible gas exists, the conductivity of the sensor will be raise according to the gas concentration goes up. Through a simple circuit, to convert the changes of conductivity to correspond to the gas concentration.TesterMeter-MIX1005 Combustible (CH4 & LPG) Gas Sensor has high sensitivity to LPG (C3H8) The sensor can work in high temperature. It is low cost sensor and can be used in different applications.

Features

High sensitivity to wide range of LPG

* High sensitivity

* Long life and low cost

* High ant seismic

Application

Domestic gas leakage detectors,Portable gas detectors

Technical Parameters

Target GasCombustible gas, LPG
Measurement Range300~10000ppm(C3H8, CH4)
Heater Voltage(Vh)5.0V±0.1V AC or DC
Loop Voltage≤24V DC
Heater Resistance(Rh)29Ω±3Ω(Room temperature)
Heater Power Consumption(Ph)≤950mW
SensitivityRs(in air)/Rs(2000ppm C3H8)≥ 5
Concentration Slope(α)≤0.6(R3000ppm/R1000ppm  C3H8)
Output In Target Gas2.5~4.0V(2000ppm C3H8)
Testing Condition20℃±2℃;55%±5%RH
Oxygen concentration in used place21%, no less than 18%
If used in low oxygen concentration, pleasure contact for detail
Life Expectancy10 years